Ceph
PLEASE NOTE: This document applies to an unreleased version of Rook. It is strongly recommended that you only use official releases of Rook, as unreleased versions are subject to changes and incompatibilities that will not be supported in the official releases.
If you are using an official release version of Rook, you should refer to the documentation for your specific version.
Documentation for other releases can be found by using the version selector in the bottom left of any doc page.Ceph Cluster CRD
Rook allows creation and customization of storage clusters through the custom resource definitions (CRDs). There are primarily three different modes in which to create your cluster.
- Specify host paths and raw devices
- Dynamically provision storage underneath Rook by specifying the storage class Rook should use to consume storage via PVCs
- Create a Stretch cluster that distributes Ceph mons across three zones, while storage (OSDs) is only configured in two zones
Following is an example for each of these approaches. More examples are included later in this doc.
Host-based Cluster
To get you started, here is a simple example of a CRD to configure a Ceph cluster with all nodes and all devices. The Ceph persistent data is stored directly on a host path (Ceph Mons) and on raw devices (Ceph OSDs).
NOTE: In addition to your CephCluster object, you need to create the namespace, service accounts, and RBAC rules for the namespace you are going to create the CephCluster in. These resources are defined in the example
common.yaml
.
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph
namespace: rook-ceph
spec:
cephVersion:
# see the "Cluster Settings" section below for more details on which image of ceph to run
image: quay.io/ceph/ceph:v16.2.7
dataDirHostPath: /var/lib/rook
mon:
count: 3
allowMultiplePerNode: false
storage:
useAllNodes: true
useAllDevices: true
onlyApplyOSDPlacement: false
PVC-based Cluster
In a “PVC-based cluster”, the Ceph persistent data is stored on volumes requested from a storage class of your choice. This type of cluster is recommended in a cloud environment where volumes can be dynamically created and also in clusters where a local PV provisioner is available.
NOTE: Kubernetes version 1.13.0 or greater is required to provision OSDs on PVCs.
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph
namespace: rook-ceph
spec:
cephVersion:
# see the "Cluster Settings" section below for more details on which image of ceph to run
image: quay.io/ceph/ceph:v16.2.7
dataDirHostPath: /var/lib/rook
mon:
count: 3
allowMultiplePerNode: false
volumeClaimTemplate:
spec:
storageClassName: gp2
resources:
requests:
storage: 10Gi
storage:
storageClassDeviceSets:
- name: set1
count: 3
portable: false
encrypted: false
volumeClaimTemplates:
- metadata:
name: data
spec:
resources:
requests:
storage: 10Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2)
storageClassName: gp2
volumeMode: Block
accessModes:
- ReadWriteOnce
onlyApplyOSDPlacement: false
For a more advanced scenario, such as adding a dedicated device you can refer to the dedicated metadata device for OSD on PVC section.
Stretch Cluster
For environments that only have two failure domains available where data can be replicated, consider the case where one failure domain is down and the data is still fully available in the remaining failure domain. To support this scenario, Ceph has recently integrated support for “stretch” clusters.
Rook requires three zones. Two zones (A and B) will each run all types of Rook pods, which we call the “data” zones. Two mons run in each of the two data zones, while two replicas of the data are in each zone for a total of four data replicas. The third zone (arbiter) runs a single mon. No other Rook or Ceph daemons need to be run in the arbiter zone.
For this example, we assume the desired failure domain is a zone. Another failure domain can also be specified with a known topology node label which is already being used for OSD failure domains.
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph
namespace: rook-ceph
spec:
dataDirHostPath: /var/lib/rook
mon:
# Five mons must be created for stretch mode
count: 5
allowMultiplePerNode: false
stretchCluster:
failureDomainLabel: topology.kubernetes.io/zone
subFailureDomain: host
zones:
- name: a
arbiter: true
- name: b
- name: c
cephVersion:
# Stretch cluster is supported in Ceph Pacific or newer.
image: quay.io/ceph/ceph:v16.2.7
allowUnsupported: true
# Either storageClassDeviceSets or the storage section can be specified for creating OSDs.
# This example uses all devices for simplicity.
storage:
useAllNodes: true
useAllDevices: true
deviceFilter: ""
# OSD placement is expected to include the non-arbiter zones
placement:
osd:
nodeAffinity:
requiredDuringSchedulingIgnoredDuringExecution:
nodeSelectorTerms:
- matchExpressions:
- key: topology.kubernetes.io/zone
operator: In
values:
- b
- c
For more details, see the Stretch Cluster design doc.
Settings
Settings can be specified at the global level to apply to the cluster as a whole, while other settings can be specified at more fine-grained levels. If any setting is unspecified, a suitable default will be used automatically.
Cluster metadata
name
: The name that will be used internally for the Ceph cluster. Most commonly the name is the same as the namespace since multiple clusters are not supported in the same namespace.namespace
: The Kubernetes namespace that will be created for the Rook cluster. The services, pods, and other resources created by the operator will be added to this namespace. The common scenario is to create a single Rook cluster. If multiple clusters are created, they must not have conflicting devices or host paths.
Cluster Settings
external
:enable
: iftrue
, the cluster will not be managed by Rook but via an external entity. This mode is intended to connect to an existing cluster. In this case, Rook will only consume the external cluster. However, Rook will be able to deploy various daemons in Kubernetes such as object gateways, mds and nfs if an image is provided and will refuse otherwise. If this setting is enabled all the other options will be ignored exceptcephVersion.image
anddataDirHostPath
. See external cluster configuration. IfcephVersion.image
is left blank, Rook will refuse the creation of extra CRs like object, file and nfs.
cephVersion
: The version information for launching the ceph daemons.image
: The image used for running the ceph daemons. For example,quay.io/ceph/ceph:v15.2.12
orv16.2.7
. For more details read the container images section. For the latest ceph images, see the Ceph DockerHub. To ensure a consistent version of the image is running across all nodes in the cluster, it is recommended to use a very specific image version. Tags also exist that would give the latest version, but they are only recommended for test environments. For example, the tagv15
will be updated each time a new Octopus build is released. Using thev15
or similar tag is not recommended in production because it may lead to inconsistent versions of the image running across different nodes in the cluster.allowUnsupported
: Iftrue
, allow an unsupported major version of the Ceph release. Currentlyoctopus
andpacific
are supported. Future versions such asquincy
would require this to be set totrue
. Should be set tofalse
in production.
dataDirHostPath
: The path on the host (hostPath) where config and data should be stored for each of the services. If the directory does not exist, it will be created. Because this directory persists on the host, it will remain after pods are deleted. Following paths and any of their subpaths must not be used:/etc/ceph
,/rook
or/var/log/ceph
.- On Minikube environments, use
/data/rook
. Minikube boots into a tmpfs but it provides some directories where files can be persisted across reboots. Using one of these directories will ensure that Rook’s data and configuration files are persisted and that enough storage space is available. - WARNING: For test scenarios, if you delete a cluster and start a new cluster on the same hosts, the path used by
dataDirHostPath
must be deleted. Otherwise, stale keys and other config will remain from the previous cluster and the new mons will fail to start. If this value is empty, each pod will get an ephemeral directory to store their config files that is tied to the lifetime of the pod running on that node. More details can be found in the Kubernetes empty dir docs.
- On Minikube environments, use
skipUpgradeChecks
: if set to true Rook won’t perform any upgrade checks on Ceph daemons during an upgrade. Use this at YOUR OWN RISK, only if you know what you’re doing. To understand Rook’s upgrade process of Ceph, read the upgrade doc.continueUpgradeAfterChecksEvenIfNotHealthy
: if set to true Rook will continue the OSD daemon upgrade process even if the PGs are not clean, or continue with the MDS upgrade even the file system is not healthy.dashboard
: Settings for the Ceph dashboard. To view the dashboard in your browser see the dashboard guide.enabled
: Whether to enable the dashboard to view cluster statusurlPrefix
: Allows to serve the dashboard under a subpath (useful when you are accessing the dashboard via a reverse proxy)port
: Allows to change the default port where the dashboard is servedssl
: Whether to serve the dashboard via SSL, ignored on Ceph versions older than13.2.2
monitoring
: Settings for monitoring Ceph using Prometheus. To enable monitoring on your cluster see the monitoring guide.enabled
: Whether to enable prometheus based monitoring for this clusterexternalMgrEndpoints
: external cluster manager endpointsexternalMgrPrometheusPort
: external prometheus manager module port. See external cluster configuration for more details.rulesNamespace
: Namespace to deploy prometheusRule. If empty, namespace of the cluster will be used. Recommended:- If you have a single Rook Ceph cluster, set the
rulesNamespace
to the same namespace as the cluster or keep it empty. - If you have multiple Rook Ceph clusters in the same Kubernetes cluster, choose the same namespace to set
rulesNamespace
for all the clusters (ideally, namespace with prometheus deployed). Otherwise, you will get duplicate alerts with duplicate alert definitions.
- If you have a single Rook Ceph cluster, set the
network
: For the network settings for the cluster, refer to the network configuration settingsmon
: contains mon related options mon settings For more details on the mons and when to choose a number other than3
, see the mon health doc.mgr
: manager top level sectioncount
: set number of ceph managers between1
to2
. The default value is 1. This is only needed if plural ceph managers are needed.modules
: is the list of Ceph manager modules to enable
crashCollector
: The settings for crash collector daemon(s).disable
: is set totrue
, the crash collector will not run on any node where a Ceph daemon runsdaysToRetain
: specifies the number of days to keep crash entries in the Ceph cluster. By default the entries are kept indefinitely.
logCollector
: The settings for log collector daemon.enabled
: if set totrue
, the log collector will run as a side-car next to each Ceph daemon. The Ceph configuration optionlog_to_file
will be turned on, meaning Ceph daemons will log on files in addition to still logging to container’s stdout. These logs will be rotated. (default: false)periodicity
: how often to rotate daemon’s log. (default: 24h). Specified with a time suffix which may be ‘h’ for hours or ‘d’ for days. Rotating too often will slightly impact the daemon’s performance since the signal briefly interrupts the program.
annotations
: annotations configuration settingslabels
: labels configuration settingsplacement
: placement configuration settingsresources
: resources configuration settingspriorityClassNames
: priority class names configuration settingsstorage
: Storage selection and configuration that will be used across the cluster. Note that these settings can be overridden for specific nodes.useAllNodes
:true
orfalse
, indicating if all nodes in the cluster should be used for storage according to the cluster level storage selection and configuration values. If individual nodes are specified under thenodes
field, thenuseAllNodes
must be set tofalse
.nodes
: Names of individual nodes in the cluster that should have their storage included in accordance with either the cluster level configuration specified above or any node specific overrides described in the next section below.useAllNodes
must be set tofalse
to use specific nodes and their config. See node settings below.config
: Config settings applied to all OSDs on the node unless overridden bydevices
. See the config settings below.- storage selection settings
- Storage Class Device Sets
onlyApplyOSDPlacement
: Whether the placement specific for OSDs is merged with theall
placement. Iffalse
, the OSD placement will be merged with theall
placement. If true, theOSD placement will be applied
and theall
placement will be ignored. The placement for OSDs is computed from several different places depending on the type of OSD:- For non-PVCs:
placement.all
andplacement.osd
- For PVCs:
placement.all
and inside the storageClassDeviceSets from theplacement
orpreparePlacement
- For non-PVCs:
managePodBudgets
: iftrue
, the operator will create and manage PodDisruptionBudgets for OSD, Mon, RGW, and MDS daemons. OSD PDBs are managed dynamically via the strategy outlined in the design. The operator will block eviction of OSDs by default and unblock them safely when drains are detected.osdMaintenanceTimeout
: is a duration in minutes that determines how long an entire failureDomain likeregion/zone/host
will be held innoout
(in addition to the default DOWN/OUT interval) when it is draining. This is only relevant whenmanagePodBudgets
istrue
. The default value is30
minutes.manageMachineDisruptionBudgets
: iftrue
, the operator will create and manage MachineDisruptionBudgets to ensure OSDs are only fenced when the cluster is healthy. Only available on OpenShift.machineDisruptionBudgetNamespace
: the namespace in which to watch the MachineDisruptionBudgets.
removeOSDsIfOutAndSafeToRemove
: Iftrue
the operator will remove the OSDs that are down and whose data has been restored to other OSDs. In Ceph terms, the OSDs areout
andsafe-to-destroy
when they are removed.cleanupPolicy
: cleanup policy settingssecurity
: security page for key management configuration
Ceph container images
Official releases of Ceph Container images are available from Docker Hub.
These are general purpose Ceph container with all necessary daemons and dependencies installed.
TAG | MEANING |
---|---|
vRELNUM | Latest release in this series (e.g., v15 = Octopus) |
vRELNUM.Y | Latest stable release in this stable series (e.g., v15.2) |
vRELNUM.Y.Z | A specific release (e.g., v15.2.5) |
vRELNUM.Y.Z-YYYYMMDD | A specific build (e.g., v15.2.11-20200419) |
A specific will contain a specific release of Ceph as well as security fixes from the Operating System.
Mon Settings
count
: Set the number of mons to be started. The number must be between1
and9
. The recommended value is most commonly3
. For highest availability, an odd number of mons should be specified. For higher durability in case of mon loss, an even number can be specified although availability may be lower. To maintain quorum a majority of mons must be up. For example, if there are three mons, two must be up. If there are four mons, three must be up. If there are two mons, both must be up. If quorum is lost, see the disaster recovery guide to restore quorum from a single mon.allowMultiplePerNode
: Whether to allow the placement of multiple mons on a single node. Default isfalse
for production. Should only be set totrue
in test environments.volumeClaimTemplate
: APersistentVolumeSpec
used by Rook to create PVCs for monitor storage. This field is optional, and when not provided, HostPath volume mounts are used. The current set of fields from template that are used arestorageClassName
and thestorage
resource request and limit. The default storage size request for new PVCs is10Gi
. Ensure that associated storage class is configured to usevolumeBindingMode: WaitForFirstConsumer
. This setting only applies to new monitors that are created when the requested number of monitors increases, or when a monitor fails and is recreated. An example CRD configuration is provided below.stretchCluster
: The stretch cluster settings that define the zones (or other failure domain labels) across which to configure the cluster.failureDomainLabel
: The label that is expected on each node where the cluster is expected to be deployed. The labels must be found in the list of well-known topology labels.subFailureDomain
: With a zone, the data replicas must be spread across OSDs in the subFailureDomain. The default ishost
.zones
: The failure domain names where the Mons and OSDs are expected to be deployed. There must be three zones specified in the list. This element is always namedzone
even if a non-defaultfailureDomainLabel
is specified. The elements have two values:name
: The name of the zone, which is the value of the domain label.arbiter
: Whether the zone is expected to be the arbiter zone which only runs a single mon. Exactly one zone must be labeledtrue
. The two zones that are not the arbiter zone are expected to have OSDs deployed.
If these settings are changed in the CRD the operator will update the number of mons during a periodic check of the mon health, which by default is every 45 seconds.
To change the defaults that the operator uses to determine the mon health and whether to failover a mon, refer to the health settings. The intervals should be small enough that you have confidence the mons will maintain quorum, while also being long enough to ignore network blips where mons are failed over too often.
Mgr Settings
You can use the cluster CR to enable or disable any manager module. This can be configured like so:
mgr:
modules:
- name: <name of the module>
enabled: true
Some modules will have special configuration to ensure the module is fully functional after being enabled. Specifically:
pg_autoscaler
: Rook will configure all new pools with PG autoscaling by setting:osd_pool_default_pg_autoscale_mode = on
Network Configuration Settings
If not specified, the default SDN will be used. Configure the network that will be enabled for the cluster and services.
provider
: Specifies the network provider that will be used to connect the network interface. You can choose betweenhost
, andmultus
.selectors
: List the network selector(s) that will be used associated by a key.ipFamily
: Specifies the network stack Ceph daemons should listen on.dualStack
: Specifies that Ceph daemon should listen on both IPv4 and IPv6 network stacks.
NOTE: Changing networking configuration after a Ceph cluster has been deployed is NOT supported and will result in a non-functioning cluster.
Host Networking
To use host networking, set provider: host
.
Multus
Rook supports addition of public and cluster network for ceph using Multus
The selector keys are required to be public
and cluster
where each represent:
public
: client communications with the cluster (reads/writes)cluster
: internal Ceph replication network
If you want to learn more, please read
Based on the configuration, the operator will do the following:
- If only the
public
selector is specified, all communication will happen on that networknetwork: provider: multus selectors: public: rook-ceph/rook-public-nw
- If only the
cluster
selector is specified, the internal cluster traffic* will happen on that network. All other traffic to mons, OSDs, and other daemons will be on the default network.network: provider: multus selectors: cluster: rook-ceph/rook-cluster-nw
- If both
public
andcluster
selectors are specified the first one will run all the communication network and the second the internal cluster network*network: provider: multus selectors: public: rook-ceph/rook-public-nw cluster: rook-ceph/rook-cluster-nw
* Internal cluster traffic includes OSD heartbeats, data replication, and data recovery
Only OSD pods will have both Public and Cluster networks attached. The rest of the Ceph component pods and CSI pods will only have the Public network attached. Rook Ceph Operator will not have any networks attached as it proxies the required commands via a sidecar container in the mgr pod.
In order to work, each selector value must match a NetworkAttachmentDefinition
object name in Multus.
For multus
network provider, an already working cluster with Multus networking is required. Network attachment definition that later will be attached to the cluster needs to be created before the Cluster CRD.
The Network attachment definitions should be using whereabouts cni.
If Rook cannot find the provided Network attachment definition it will fail running the Ceph OSD pods.
You can add the Multus network attachment selection annotation selecting the created network attachment definition on selectors
.
A valid NetworkAttachmentDefinition will look like following:
apiVersion: "k8s.cni.cncf.io/v1"
kind: NetworkAttachmentDefinition
metadata:
name: rook-public-nw
spec:
config: '{
"cniVersion": "0.3.0",
"name": "public-nad",
"type": "macvlan",
"master": "ens5",
"mode": "bridge",
"ipam": {
"type": "whereabouts",
"range": "192.168.1.0/24"
}
}'
- Ensure that
master
matches the network interface of the host that you want to use. - Ipam type
whereabouts
is required because it makes sure that all the pods get a unique IP address from the multus network. - The NetworkAttachmentDefinition should be referenced along with the namespace in which it is present like
public: <namespace>/<name of NAD>
. e.g., the network attachment definition are indefault
namespace:public: default/rook-public-nw cluster: default/rook-cluster-nw
- This format is required in order to use the NetworkAttachmentDefinition across namespaces.
- In Openshift, to use a NetworkAttachmentDefinition (NAD) across namespaces, the NAD must be deployed in the
default
namespace. The NAD is then referenced with the namespace:default/rook-public-nw
Known issues with multus
When a CephFS/RBD volume is mounted in a Pod using cephcsi and then the CSI CephFS/RBD plugin is restarted or terminated (e.g. by restarting or deleting its DaemonSet), all operations on the volume become blocked, even after restarting the CSI pods. The only workaround is to restart the node where the cephcsi plugin pod was restarted. This issue is tracked here.
IPFamily
Provide single-stack IPv4 or IPv6 protocol to assign corresponding addresses to pods and services. This field is optional. Possible inputs are IPv6 and IPv4. Empty value will be treated as IPv4. Kubernetes version should be at least v1.13 to run IPv6. Dual-stack is supported as of ceph Pacific. To turn on dual stack see the network configuration section.
Node Settings
In addition to the cluster level settings specified above, each individual node can also specify configuration to override the cluster level settings and defaults. If a node does not specify any configuration then it will inherit the cluster level settings.
name
: The name of the node, which should match itskubernetes.io/hostname
label.config
: Config settings applied to all OSDs on the node unless overridden bydevices
. See the config settings below.- storage selection settings
When useAllNodes
is set to true
, Rook attempts to make Ceph cluster management as hands-off as
possible while still maintaining reasonable data safety. If a usable node comes online, Rook will
begin to use it automatically. To maintain a balance between hands-off usability and data safety,
Nodes are removed from Ceph as OSD hosts only (1) if the node is deleted from Kubernetes itself or
(2) if the node has its taints or affinities modified in such a way that the node is no longer
usable by Rook. Any changes to taints or affinities, intentional or unintentional, may affect the
data reliability of the Ceph cluster. In order to help protect against this somewhat, deletion of
nodes by taint or affinity modifications must be “confirmed” by deleting the Rook-Ceph operator pod
and allowing the operator deployment to restart the pod.
For production clusters, we recommend that useAllNodes
is set to false
to prevent the Ceph
cluster from suffering reduced data reliability unintentionally due to a user mistake. When
useAllNodes
is set to false
, Rook relies on the user to be explicit about when nodes are added
to or removed from the Ceph cluster. Nodes are only added to the Ceph cluster if the node is added
to the Ceph cluster resource. Similarly, nodes are only removed if the node is removed from the Ceph
cluster resource.
Node Updates
Nodes can be added and removed over time by updating the Cluster CRD, for example with kubectl -n rook-ceph edit cephcluster rook-ceph
.
This will bring up your default text editor and allow you to add and remove storage nodes from the cluster.
This feature is only available when useAllNodes
has been set to false
.
Storage Selection Settings
Below are the settings for host-based cluster. This type of cluster can specify devices for OSDs, both at the cluster and individual node level, for selecting which storage resources will be included in the cluster.
useAllDevices
:true
orfalse
, indicating whether all devices found on nodes in the cluster should be automatically consumed by OSDs. Not recommended unless you have a very controlled environment where you will not risk formatting of devices with existing data. Whentrue
, all devices/partitions will be used. Is overridden bydeviceFilter
if specified.deviceFilter
: A regular expression for short kernel names of devices (e.g.sda
) that allows selection of devices to be consumed by OSDs. If individual devices have been specified for a node then this filter will be ignored. This field uses golang regular expression syntax. For example:sdb
: Only selects thesdb
device if found^sd.
: Selects all devices starting withsd
^sd[a-d]
: Selects devices starting withsda
,sdb
,sdc
, andsdd
if found^s
: Selects all devices that start withs
^[^r]
: Selects all devices that do not start withr
devicePathFilter
: A regular expression for device paths (e.g./dev/disk/by-path/pci-0:1:2:3-scsi-1
) that allows selection of devices to be consumed by OSDs. If individual devices ordeviceFilter
have been specified for a node then this filter will be ignored. This field uses golang regular expression syntax. For example:^/dev/sd.
: Selects all devices starting withsd
^/dev/disk/by-path/pci-.*
: Selects all devices which are connected to PCI bus
devices
: A list of individual device names belonging to this node to include in the storage cluster.name
: The name of the device (e.g.,sda
), or full udev path (e.g./dev/disk/by-id/ata-ST4000DM004-XXXX
- this will not change after reboots).config
: Device-specific config settings. See the config settings below
Host-based cluster only supports raw device and partition. Be sure to see the Ceph quickstart doc prerequisites for additional considerations.
Below are the settings for a PVC-based cluster.
storageClassDeviceSets
: Explained in Storage Class Device Sets
Storage Class Device Sets
The following are the settings for Storage Class Device Sets which can be configured to create OSDs that are backed by block mode PVs.
name
: A name for the set.count
: The number of devices in the set.resources
: The CPU and RAM requests/limits for the devices. (Optional)-
placement
: The placement criteria for the devices. (Optional) Default is no placement criteria.The syntax is the same as for other placement configuration. It supports
nodeAffinity
,podAffinity
,podAntiAffinity
andtolerations
keys.It is recommended to configure the placement such that the OSDs will be as evenly spread across nodes as possible. At a minimum, anti-affinity should be added so at least one OSD will be placed on each available nodes.
However, if there are more OSDs than nodes, this anti-affinity will not be effective. Another placement scheme to consider is to add labels to the nodes in such a way that the OSDs can be grouped on those nodes, create multiple storageClassDeviceSets, and add node affinity to each of the device sets that will place the OSDs in those sets of nodes.
Rook will automatically add required nodeAffinity to the OSD daemons to match the topology labels that are found on the nodes where the OSD prepare jobs ran. To ensure data durability, the OSDs are required to run in the same topology that the Ceph CRUSH map expects. For example, if the nodes are labeled with rack topology labels, the OSDs will be constrained to a certain rack. Without the topology labels, Rook will not constrain the OSDs beyond what is required by the PVs, for example to run in the zone where provisioned. See the OSD Topology section for the related labels.
preparePlacement
: The placement criteria for the preparation of the OSD devices. Creating OSDs is a two-step process and the prepare job may require different placement than the OSD daemons. If thepreparePlacement
is not specified, theplacement
will instead be applied for consistent placement for the OSD prepare jobs and OSD deployments. ThepreparePlacement
is only useful forportable
OSDs in the device sets. OSDs that are not portable will be tied to the host where the OSD prepare job initially runs.- For example, provisioning may require topology spread constraints across zones, but the OSD daemons may require constraints across hosts within the zones.
portable
: Iftrue
, the OSDs will be allowed to move between nodes during failover. This requires a storage class that supports portability (e.g.aws-ebs
, but not the local storage provisioner). Iffalse
, the OSDs will be assigned to a node permanently. Rook will configure Ceph’s CRUSH map to support the portability.tuneDeviceClass
: For example, Ceph cannot detect AWS volumes as HDDs from the storage class “gp2”, so you can improve Ceph performance by setting this to true.tuneFastDeviceClass
: For example, Ceph cannot detect Azure disks as SSDs from the storage class “managed-premium”, so you can improve Ceph performance by setting this to true..volumeClaimTemplates
: A list of PVC templates to use for provisioning the underlying storage devices.resources.requests.storage
: The desired capacity for the underlying storage devices.storageClassName
: The StorageClass to provision PVCs from. Default would be to use the cluster-default StorageClass. This StorageClass should provide a raw block device, multipath device, or logical volume. Other types are not supported. If you want to use logical volume, please see known issue of OSD on LV-backed PVCvolumeMode
: The volume mode to be set for the PVC. Which should be BlockaccessModes
: The access mode for the PVC to be bound by OSD.
schedulerName
: Scheduler name for OSD pod placement. (Optional)encrypted
: whether to encrypt all the OSDs in a given storageClassDeviceSet
OSD Configuration Settings
The following storage selection settings are specific to Ceph and do not apply to other backends. All variables are key-value pairs represented as strings.
metadataDevice
: Name of a device to use for the metadata of OSDs on each node. Performance can be improved by using a low latency device (such as SSD or NVMe) as the metadata device, while other spinning platter (HDD) devices on a node are used to store data. Provisioning will fail if the user specifies ametadataDevice
but that device is not used as a metadata device by Ceph. Notably,ceph-volume
will not use a device of the same device class (HDD, SSD, NVMe) as OSD devices for metadata, resulting in this failure.databaseSizeMB
: The size in MB of a bluestore database. Include quotes around the size.walSizeMB
: The size in MB of a bluestore write ahead log (WAL). Include quotes around the size.deviceClass
: The CRUSH device class to use for this selection of storage devices. (By default, if a device’s class has not already been set, OSDs will automatically set a device’s class to eitherhdd
,ssd
, ornvme
based on the hardware properties exposed by the Linux kernel.) These storage classes can then be used to select the devices backing a storage pool by specifying them as the value of the pool spec’sdeviceClass
field.initialWeight
: The initial OSD weight in TiB units. By default, this value is derived from OSD’s capacity.primaryAffinity
: The primary-affinity value of an OSD, within range[0, 1]
(default:1
).osdsPerDevice
**: The number of OSDs to create on each device. High performance devices such as NVMe can handle running multiple OSDs. If desired, this can be overridden for each node and each device.encryptedDevice
**: Encrypt OSD volumes using dmcrypt (“true” or “false”). By default this option is disabled. See encryption for more information on encryption in Ceph.crushRoot
: The value of theroot
CRUSH map label. The default isdefault
. Generally, you should not need to change this. However, if any of your topology labels may have the valuedefault
, you need to changecrushRoot
to avoid conflicts, since CRUSH map values need to be unique.
Annotations and Labels
Annotations and Labels can be specified so that the Rook components will have those annotations / labels added to them.
You can set annotations / labels for Rook components for the list of key value pairs:
all
: Set annotations / labels for all componentsmgr
: Set annotations / labels for MGRsmon
: Set annotations / labels for monsosd
: Set annotations / labels for OSDsprepareosd
: Set annotations / labels for OSD Prepare Jobsmonitoring
: Set annotations / labels for service monitorcrashcollector
: Set annotations / labels for crash collectors When other keys are set,all
will be merged together with the specific component.
Placement Configuration Settings
Placement configuration for the cluster services. It includes the following keys: mgr
, mon
, arbiter
, osd
, cleanup
, and all
.
Each service will have its placement configuration generated by merging the generic configuration under all
with the most specific one (which will override any attributes).
In stretch clusters, if the arbiter
placement is specified, that placement will only be applied to the arbiter.
Neither will the arbiter
placement be merged with the all
placement to allow the arbiter to be fully independent of other daemon placement.
The remaining mons will still use the mon
and/or all
sections.
NOTE: Placement of OSD pods is controlled using the Storage Class Device Set, not the general placement
configuration.
A Placement configuration is specified (according to the kubernetes PodSpec) as:
nodeAffinity
: kubernetes NodeAffinitypodAffinity
: kubernetes PodAffinitypodAntiAffinity
: kubernetes PodAntiAffinitytolerations
: list of kubernetes TolerationtopologySpreadConstraints
: kubernetes TopologySpreadConstraints
If you use labelSelector
for osd
pods, you must write two rules both for rook-ceph-osd
and rook-ceph-osd-prepare
like the example configuration. It comes from the design that there are these two pods for an OSD. For more detail, see the osd design doc and the related issue.
The Rook Ceph operator creates a Job called rook-ceph-detect-version
to detect the full Ceph version used by the given cephVersion.image
. The placement from the mon
section is used for the Job except for the PodAntiAffinity
field.
Cluster-wide Resources Configuration Settings
Resources should be specified so that the Rook components are handled after Kubernetes Pod Quality of Service classes. This allows to keep Rook components running when for example a node runs out of memory and the Rook components are not killed depending on their Quality of Service class.
You can set resource requests/limits for Rook components through the Resource Requirements/Limits structure in the following keys:
mon
: Set resource requests/limits for monsosd
: Set resource requests/limits for OSDs. This key applies for all OSDs regardless of their device classes. In case of need to apply resource requests/limits for OSDs with particular device class use specific osd keys below. If the memory resource is declared Rook will automatically set the OSD configurationosd_memory_target
to the same value. This aims to ensure that the actual OSD memory consumption is consistent with the OSD pods’ resource declaration.osd-<deviceClass>
: Set resource requests/limits for OSDs on a specific device class. Rook will automatically detecthdd
,ssd
, ornvme
device classes. Custom device classes can also be set.mgr
: Set resource requests/limits for MGRsmgr-sidecar
: Set resource requests/limits for the MGR sidecar, which is only created whenmgr.count: 2
. The sidecar requires very few resources since it only executes every 15 seconds to query Ceph for the active mgr and update the mgr services if the active mgr changed.prepareosd
: Set resource requests/limits for OSD prepare jobcrashcollector
: Set resource requests/limits for crash. This pod runs wherever there is a Ceph pod running. It scrapes for Ceph daemon core dumps and sends them to the Ceph manager crash module so that core dumps are centralized and can be easily listed/accessed. You can read more about the Ceph Crash module.logcollector
: Set resource requests/limits for the log collector. When enabled, this container runs as side-car to each Ceph daemons.cleanup
: Set resource requests/limits for cleanup job, responsible for wiping cluster’s data after uninstall
In order to provide the best possible experience running Ceph in containers, Rook internally recommends minimum memory limits if resource limits are passed. If a user configures a limit or request value that is too low, Rook will still run the pod(s) and print a warning to the operator log.
mon
: 1024MBmgr
: 512MBosd
: 2048MBprepareosd
: 50MBcrashcollector
: 60MBmgr-sidecar
: 100MB limit, 40MB requests
HINT The resources for MDS daemons are not configured in the Cluster. Refer to the Ceph Filesystem CRD instead.
Resource Requirements/Limits
For more information on resource requests/limits see the official Kubernetes documentation: Kubernetes - Managing Compute Resources for Containers
requests
: Requests for cpu or memory.cpu
: Request for CPU (example: one CPU core1
, 50% of one CPU core500m
).memory
: Limit for Memory (example: one gigabyte of memory1Gi
, half a gigabyte of memory512Mi
).
limits
: Limits for cpu or memory.cpu
: Limit for CPU (example: one CPU core1
, 50% of one CPU core500m
).memory
: Limit for Memory (example: one gigabyte of memory1Gi
, half a gigabyte of memory512Mi
).
Priority Class Names Configuration Settings
Priority class names can be specified so that the Rook components will have those priority class names added to them.
You can set priority class names for Rook components for the list of key value pairs:
all
: Set priority class names for MGRs, Mons, OSDs.mgr
: Set priority class names for MGRs.mon
: Set priority class names for Mons.osd
: Set priority class names for OSDs.
The specific component keys will act as overrides to all
.
Health settings
Rook-Ceph will monitor the state of the CephCluster on various components by default. The following CRD settings are available:
healthCheck
: main ceph cluster health monitoring section
Currently three health checks are implemented:
mon
: health check on the ceph monitors, basically check whether monitors are members of the quorum. If after a certain timeout a given monitor has not joined the quorum back it will be failed over and replace by a new monitor.osd
: health check on the ceph osdsstatus
: ceph health status check, periodically check the Ceph health state and reflects it in the CephCluster CR status field.
The liveness probe of each daemon can also be controlled via livenessProbe
, the setting is valid for mon
, mgr
and osd
.
Here is a complete example for both daemonHealth
and livenessProbe
:
healthCheck:
daemonHealth:
mon:
disabled: false
interval: 45s
timeout: 600s
osd:
disabled: false
interval: 60s
status:
disabled: false
livenessProbe:
mon:
disabled: false
mgr:
disabled: false
osd:
disabled: false
The probe itself can also be overridden, refer to the Kubernetes documentation.
For example, you could change the mgr
probe by applying:
healthCheck:
livenessProbe:
mgr:
disabled: false
probe:
httpGet:
path: /
port: 9283
initialDelaySeconds: 3
periodSeconds: 3
Changing the liveness probe is an advanced operation and should rarely be necessary. If you want to change these settings then modify the desired settings.
Status
The operator is regularly configuring and checking the health of the cluster. The results of the configuration
and health checks can be seen in the status
section of the CephCluster CR.
kubectl -n rook-ceph get CephCluster -o yaml
...
status:
ceph:
health: HEALTH_OK
lastChecked: "2021-03-02T21:22:11Z"
capacity:
bytesAvailable: 22530293760
bytesTotal: 25757220864
bytesUsed: 3226927104
lastUpdated: "2021-03-02T21:22:11Z"
message: Cluster created successfully
phase: Ready
state: Created
storage:
deviceClasses:
- name: hdd
version:
image: quay.io/ceph/ceph:v16.2.7
version: 16.2.6-0
conditions:
- lastHeartbeatTime: "2021-03-02T21:22:11Z"
lastTransitionTime: "2021-03-02T21:21:09Z"
message: Cluster created successfully
reason: ClusterCreated
status: "True"
type: Ready
Ceph Status
Ceph is constantly monitoring the health of the data plane and reporting back if there are
any warnings or errors. If everything is healthy from Ceph’s perspective, you will see
HEALTH_OK
.
If Ceph reports any warnings or errors, the details will be printed to the status.
If further troubleshooting is needed to resolve these issues, the toolbox will likely
be needed where you can run ceph
commands to find more details.
The capacity
of the cluster is reported, including bytes available, total, and used.
The available space will be less that you may expect due to overhead in the OSDs.
Conditions
The conditions
represent the status of the Rook operator.
- If the cluster is fully configured and the operator is stable, the
Ready
condition is raised withClusterCreated
reason and no other conditions. The cluster will remain in theReady
condition after the first successful configuration since it is expected the storage is consumable from this point on. If there are issues preventing the storage layer from working, they are expected to show as Ceph health errors. - If the cluster is externally connected successfully, the
Ready
condition will have the reasonClusterConnected
. - If the operator is currently being configured or the operator is checking for update,
there will be a
Progressing
condition. - If there was a failure, the condition(s) status will be
false
and themessage
will give a summary of the error. See the operator log for more details.
Other Status
There are several other properties for the overall status including:
message
,phase
, andstate
: A summary of the overall current state of the cluster, which is somewhat duplicated from the conditions for backward compatibility.storage.deviceClasses
: The names of the types of storage devices that Ceph discovered in the cluster. These types will bessd
orhdd
unless they have been overridden with thecrushDeviceClass
in thestorageClassDeviceSets
.version
: The version of the Ceph image currently deployed.
Samples
Here are several samples for configuring Ceph clusters. Each of the samples must also include the namespace and corresponding access granted for management by the Ceph operator. See the common cluster resources below.
Storage configuration: All devices
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph
namespace: rook-ceph
spec:
cephVersion:
image: quay.io/ceph/ceph:v16.2.7
dataDirHostPath: /var/lib/rook
mon:
count: 3
allowMultiplePerNode: false
dashboard:
enabled: true
# cluster level storage configuration and selection
storage:
useAllNodes: true
useAllDevices: true
deviceFilter:
config:
metadataDevice:
databaseSizeMB: "1024" # this value can be removed for environments with normal sized disks (100 GB or larger)
journalSizeMB: "1024" # this value can be removed for environments with normal sized disks (20 GB or larger)
osdsPerDevice: "1"
Storage Configuration: Specific devices
Individual nodes and their config can be specified so that only the named nodes below will be used as storage resources. Each node’s ‘name’ field should match their ‘kubernetes.io/hostname’ label.
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph
namespace: rook-ceph
spec:
cephVersion:
image: quay.io/ceph/ceph:v16.2.7
dataDirHostPath: /var/lib/rook
mon:
count: 3
allowMultiplePerNode: false
dashboard:
enabled: true
# cluster level storage configuration and selection
storage:
useAllNodes: false
useAllDevices: false
deviceFilter:
config:
metadataDevice:
databaseSizeMB: "1024" # this value can be removed for environments with normal sized disks (100 GB or larger)
nodes:
- name: "172.17.4.201"
devices: # specific devices to use for storage can be specified for each node
- name: "sdb" # Whole storage device
- name: "sdc1" # One specific partition. Should not have a file system on it.
- name: "/dev/disk/by-id/ata-ST4000DM004-XXXX" # both device name and explicit udev links are supported
config: # configuration can be specified at the node level which overrides the cluster level config
- name: "172.17.4.301"
deviceFilter: "^sd."
Node Affinity
To control where various services will be scheduled by kubernetes, use the placement configuration sections below. The example under ‘all’ would have all services scheduled on kubernetes nodes labeled with ‘role=storage-node’ and tolerate taints with a key of ‘storage-node’.
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph
namespace: rook-ceph
spec:
cephVersion:
image: quay.io/ceph/ceph:v16.2.7
dataDirHostPath: /var/lib/rook
mon:
count: 3
allowMultiplePerNode: false
# enable the ceph dashboard for viewing cluster status
dashboard:
enabled: true
placement:
all:
nodeAffinity:
requiredDuringSchedulingIgnoredDuringExecution:
nodeSelectorTerms:
- matchExpressions:
- key: role
operator: In
values:
- storage-node
tolerations:
- key: storage-node
operator: Exists
mgr:
nodeAffinity:
tolerations:
mon:
nodeAffinity:
tolerations:
osd:
nodeAffinity:
tolerations:
Resource Requests/Limits
To control how many resources the Rook components can request/use, you can set requests and limits in Kubernetes for them.
You can override these requests/limits for OSDs per node when using useAllNodes: false
in the node
item in the nodes
list.
WARNING: Before setting resource requests/limits, please take a look at the Ceph documentation for recommendations for each component: Ceph - Hardware Recommendations.
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph
namespace: rook-ceph
spec:
cephVersion:
image: quay.io/ceph/ceph:v16.2.7
dataDirHostPath: /var/lib/rook
mon:
count: 3
allowMultiplePerNode: false
# enable the ceph dashboard for viewing cluster status
dashboard:
enabled: true
# cluster level resource requests/limits configuration
resources:
storage:
useAllNodes: false
nodes:
- name: "172.17.4.201"
resources:
limits:
cpu: "2"
memory: "4096Mi"
requests:
cpu: "2"
memory: "4096Mi"
OSD Topology
The topology of the cluster is important in production environments where you want your data spread across failure domains. The topology can be controlled by adding labels to the nodes. When the labels are found on a node at first OSD deployment, Rook will add them to the desired level in the CRUSH map.
The complete list of labels in hierarchy order from highest to lowest is:
topology.kubernetes.io/region
topology.kubernetes.io/zone
topology.rook.io/datacenter
topology.rook.io/room
topology.rook.io/pod
topology.rook.io/pdu
topology.rook.io/row
topology.rook.io/rack
topology.rook.io/chassis
For example, if the following labels were added to a node:
kubectl label node mynode topology.kubernetes.io/zone=zone1
kubectl label node mynode topology.rook.io/rack=zone1-rack1
For versions previous to K8s 1.17, use the topology key: failure-domain.beta.kubernetes.io/zone or region
These labels would result in the following hierarchy for OSDs on that node (this command can be run in the Rook toolbox):
ceph osd tree
ID CLASS WEIGHT TYPE NAME STATUS REWEIGHT PRI-AFF -1 0.01358 root default -5 0.01358 zone zone1 -4 0.01358 rack rack1 -3 0.01358 host mynode 0 hdd 0.00679 osd.0 up 1.00000 1.00000 1 hdd 0.00679 osd.1 up 1.00000 1.00000
Ceph requires unique names at every level in the hierarchy (CRUSH map). For example, you cannot have two racks with the same name that are in different zones. Racks in different zones must be named uniquely.
Note that the host
is added automatically to the hierarchy by Rook. The host cannot be specified with a topology label.
All topology labels are optional.
HINT When setting the node labels prior to
CephCluster
creation, these settings take immediate effect. However, applying this to an already deployedCephCluster
requires removing each node from the cluster first and then re-adding it with new configuration to take effect. Do this node by node to keep your data safe! Check the result withceph osd tree
from the Rook Toolbox. The OSD tree should display the hierarchy for the nodes that already have been re-added.
To utilize the failureDomain
based on the node labels, specify the corresponding option in the CephBlockPool
apiVersion: ceph.rook.io/v1
kind: CephBlockPool
metadata:
name: replicapool
namespace: rook-ceph
spec:
failureDomain: rack # this matches the topology labels on nodes
replicated:
size: 3
This configuration will split the replication of volumes across unique racks in the data center setup.
Using PVC storage for monitors
In the CRD specification below three monitors are created each using a 10Gi PVC
created by Rook using the local-storage
storage class.
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph
namespace: rook-ceph
spec:
cephVersion:
image: quay.io/ceph/ceph:v16.2.7
dataDirHostPath: /var/lib/rook
mon:
count: 3
allowMultiplePerNode: false
volumeClaimTemplate:
spec:
storageClassName: local-storage
resources:
requests:
storage: 10Gi
dashboard:
enabled: true
storage:
useAllNodes: true
useAllDevices: true
deviceFilter:
config:
metadataDevice:
databaseSizeMB: "1024" # this value can be removed for environments with normal sized disks (100 GB or larger)
journalSizeMB: "1024" # this value can be removed for environments with normal sized disks (20 GB or larger)
osdsPerDevice: "1"
Using StorageClassDeviceSets
In the CRD specification below, 3 OSDs (having specific placement and resource values) and 3 mons with each using a 10Gi PVC, are created by Rook using the local-storage
storage class.
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph
namespace: rook-ceph
spec:
dataDirHostPath: /var/lib/rook
mon:
count: 3
allowMultiplePerNode: false
volumeClaimTemplate:
spec:
storageClassName: local-storage
resources:
requests:
storage: 10Gi
cephVersion:
image: quay.io/ceph/ceph:v16.2.7
allowUnsupported: false
dashboard:
enabled: true
network:
hostNetwork: false
storage:
storageClassDeviceSets:
- name: set1
count: 3
portable: false
resources:
limits:
cpu: "500m"
memory: "4Gi"
requests:
cpu: "500m"
memory: "4Gi"
placement:
podAntiAffinity:
preferredDuringSchedulingIgnoredDuringExecution:
- weight: 100
podAffinityTerm:
labelSelector:
matchExpressions:
- key: "rook.io/cluster"
operator: In
values:
- cluster1
topologyKey: "topology.kubernetes.io/zone"
volumeClaimTemplates:
- metadata:
name: data
spec:
resources:
requests:
storage: 10Gi
storageClassName: local-storage
volumeMode: Block
accessModes:
- ReadWriteOnce
Dedicated metadata and wal device for OSD on PVC
In the simplest case, Ceph OSD BlueStore consumes a single (primary) storage device. BlueStore is the engine used by the OSD to store data.
The storage device is normally used as a whole, occupying the full device that is managed directly by BlueStore. It is also possible to deploy BlueStore across additional devices such as a DB device. This device can be used for storing BlueStore’s internal metadata. BlueStore (or rather, the embedded RocksDB) will put as much metadata as it can on the DB device to improve performance. If the DB device fills up, metadata will spill back onto the primary device (where it would have been otherwise). Again, it is only helpful to provision a DB device if it is faster than the primary device.
You can have multiple volumeClaimTemplates
where each might either represent a device or a metadata device.
So just taking the storage
section this will give something like:
storage:
storageClassDeviceSets:
- name: set1
count: 3
portable: false
volumeClaimTemplates:
- metadata:
name: data
spec:
resources:
requests:
storage: 10Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2)
storageClassName: gp2
volumeMode: Block
accessModes:
- ReadWriteOnce
- metadata:
name: metadata
spec:
resources:
requests:
# Find the right size https://docs.ceph.com/docs/master/rados/configuration/bluestore-config-ref/#sizing
storage: 5Gi
# IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, io1)
storageClassName: io1
volumeMode: Block
accessModes:
- ReadWriteOnce
NOTE: Note that Rook only supports three naming convention for a given template:
- “data”: represents the main OSD block device, where your data is being stored.
- “metadata”: represents the metadata (including block.db and block.wal) device used to store the Ceph Bluestore database for an OSD.
- “wal”: represents the block.wal device used to store the Ceph Bluestore database for an OSD. If this device is set, “metadata” device will refer specifically to block.db device. It is recommended to use a faster storage class for the metadata or wal device, with a slower device for the data. Otherwise, having a separate metadata device will not improve the performance.
The bluestore partition has the following reference combinations supported by the ceph-volume utility:
-
A single “data” device.
storage: storageClassDeviceSets: - name: set1 count: 3 portable: false volumeClaimTemplates: - metadata: name: data spec: resources: requests: storage: 10Gi # IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2) storageClassName: gp2 volumeMode: Block accessModes: - ReadWriteOnce
-
A “data” device and a “metadata” device.
storage: storageClassDeviceSets: - name: set1 count: 3 portable: false volumeClaimTemplates: - metadata: name: data spec: resources: requests: storage: 10Gi # IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2) storageClassName: gp2 volumeMode: Block accessModes: - ReadWriteOnce - metadata: name: metadata spec: resources: requests: # Find the right size https://docs.ceph.com/docs/master/rados/configuration/bluestore-config-ref/#sizing storage: 5Gi # IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, io1) storageClassName: io1 volumeMode: Block accessModes: - ReadWriteOnce
-
A “data” device and a “wal” device. A WAL device can be used for BlueStore’s internal journal or write-ahead log (block.wal), it is only useful to use a WAL device if the device is faster than the primary device (data device). There is no separate “metadata” device in this case, the data of main OSD block and block.db located in “data” device.
storage: storageClassDeviceSets: - name: set1 count: 3 portable: false volumeClaimTemplates: - metadata: name: data spec: resources: requests: storage: 10Gi # IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2) storageClassName: gp2 volumeMode: Block accessModes: - ReadWriteOnce - metadata: name: wal spec: resources: requests: # Find the right size https://docs.ceph.com/docs/master/rados/configuration/bluestore-config-ref/#sizing storage: 5Gi # IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, io1) storageClassName: io1 volumeMode: Block accessModes: - ReadWriteOnce
-
A “data” device, a “metadata” device and a “wal” device.
storage: storageClassDeviceSets: - name: set1 count: 3 portable: false volumeClaimTemplates: - metadata: name: data spec: resources: requests: storage: 10Gi # IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, gp2) storageClassName: gp2 volumeMode: Block accessModes: - ReadWriteOnce - metadata: name: metadata spec: resources: requests: # Find the right size https://docs.ceph.com/docs/master/rados/configuration/bluestore-config-ref/#sizing storage: 5Gi # IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, io1) storageClassName: io1 volumeMode: Block accessModes: - ReadWriteOnce - metadata: name: wal spec: resources: requests: # Find the right size https://docs.ceph.com/docs/master/rados/configuration/bluestore-config-ref/#sizing storage: 5Gi # IMPORTANT: Change the storage class depending on your environment (e.g. local-storage, io1) storageClassName: io1 volumeMode: Block accessModes: - ReadWriteOnce
To determine the size of the metadata block follow the official Ceph sizing guide.
With the present configuration, each OSD will have its main block allocated a 10GB device as well a 5GB device to act as a bluestore database.
External cluster
The minimum supported Ceph version for the External Cluster is Luminous 12.2.x.
The features available from the external cluster will vary depending on the version of Ceph. The following table shows the minimum version of Ceph for some of the features:
FEATURE | CEPH VERSION |
---|---|
Dynamic provisioning RBD | 12.2.X |
Configure extra CRDs (object, file, nfs)1 | 13.2.3 |
Dynamic provisioning CephFS | 14.2.3 |
Pre-requisites
In order to configure an external Ceph cluster with Rook, we need to inject some information in order to connect to that cluster.
You can use the deploy/examples/import-external-cluster.sh
script to achieve that.
The script will look for the following populated environment variables:
NAMESPACE
: the namespace where the configmap and secrets should be injectedROOK_EXTERNAL_FSID
: the fsid of the external Ceph cluster, it can be retrieved via theceph fsid
commandROOK_EXTERNAL_CEPH_MON_DATA
: is a common-separated list of running monitors IP address along with their ports, e.g:a=172.17.0.4:3300,b=172.17.0.5:3300,c=172.17.0.6:3300
. You don’t need to specify all the monitors, you can simply pass one and the Operator will discover the rest. The name of the monitor is the name that appears in theceph status
output.
Now, we need to give Rook a key to connect to the cluster in order to perform various operations such as health cluster check, CSI keys management etc… It is recommended to generate keys with minimal access so the admin key does not need to be used by the external cluster. In this case, the admin key is only needed to generate the keys that will be used by the external cluster. But if the admin key is to be used by the external cluster, set the following variable:
ROOK_EXTERNAL_ADMIN_SECRET
: OPTIONAL: the external Ceph cluster admin secret key, it can be retrieved via theceph auth get-key client.admin
command.
WARNING: If you plan to create CRs (pool, rgw, mds, nfs) in the external cluster, you MUST inject the client.admin keyring as well as injecting
cluster-external-management.yaml
Example:
export NAMESPACE=rook-ceph-external
export ROOK_EXTERNAL_FSID=3240b4aa-ddbc-42ee-98ba-4ea7b2a61514
export ROOK_EXTERNAL_CEPH_MON_DATA=a=172.17.0.4:3300
export ROOK_EXTERNAL_ADMIN_SECRET=AQC6Ylxdja+NDBAAB7qy9MEAr4VLLq4dCIvxtg==
If the Ceph admin key is not provided, the following script needs to be executed on a machine that can connect to the Ceph cluster using the Ceph admin key. On that machine, run:
. deploy/examples/create-external-cluster-resources.sh
The script will source all the necessary environment variables for you. It assumes the namespace name is rook-ceph-external
.
This can be changed by running the script like (assuming namespace name is foo
this time):
ns=foo . deploy/examples/create-external-cluster-resources.sh
When done you can execute: import-external-cluster.sh
to inject them in your Kubernetes cluster.
WARNING: Since only Ceph admin key can create CRs in the external cluster, please make sure that rgw pools have been prepared. You can get existing pools by running
ceph osd pool ls
.
Example:
ceph osd pool ls
my-store.rgw.control my-store.rgw.meta my-store.rgw.log my-store.rgw.buckets.index my-store.rgw.buckets.non-ec my-store.rgw.buckets.data
In this example, you can simply export RGW_POOL_PREFIX before executing the script like this:
export RGW_POOL_PREFIX=my-store
The script will automatically create users and keys with the lowest possible privileges and populate the necessary environment variables for deploy/examples/import-external-cluster.sh
to work correctly.
Finally, you can simply execute the script like this from a machine that has access to your Kubernetes cluster:
bash deploy/examples/import-external-cluster.sh
CephCluster example (consumer)
Assuming the above section has successfully completed, here is a CR example:
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph-external
namespace: rook-ceph-external
spec:
external:
enable: true
crashCollector:
disable: true
# optionally, the ceph-mgr IP address can be pass to gather metric from the prometheus exporter
#monitoring:
#enabled: true
#rulesNamespace: rook-ceph
#externalMgrEndpoints:
#- ip: 192.168.39.182
#externalMgrPrometheusPort: 9283
Choose the namespace carefully, if you have an existing cluster managed by Rook, you have likely already injected common.yaml
.
Additionally, you now need to inject common-external.yaml
too.
You can now create it like this:
kubectl create -f deploy/examples/cluster-external.yaml
If the previous section has not been completed, the Rook Operator will still acknowledge the CR creation but will wait forever to receive connection information.
WARNING: If no cluster is managed by the current Rook Operator, you need to inject
common.yaml
, then modifycluster-external.yaml
and specifyrook-ceph
asnamespace
.
If this is successful you will see the CepCluster status as connected.
kubectl get CephCluster -n rook-ceph-external
NAME DATADIRHOSTPATH MONCOUNT AGE STATE HEALTH rook-ceph-external /var/lib/rook 162m Connected HEALTH_OK
Before you create a StorageClass with this cluster you will need to create a Pool in your external Ceph Cluster.
Example StorageClass based on external Ceph Pool
In Ceph Cluster let us list the pools available:
rados df
POOL_NAME USED OBJECTS CLONES COPIES MISSING_ON_PRIMARY UNFOUND DEGRADED RD_OPS RD WR_OPS WR USED COMPR UNDER COMPR replicated_2g 0 B 0 0 0 0 0 0 0 0 B 0 0 B 0 B 0 B
Here is an example StorageClass configuration that uses the replicated_2g
pool from the external cluster:
cat << EOF | kubectl apply -f -
apiVersion: storage.k8s.io/v1 kind: StorageClass metadata: name: rook-ceph-block-ext # Change "rook-ceph" provisioner prefix to match the operator namespace if needed provisioner: rook-ceph.rbd.csi.ceph.com parameters: # clusterID is the namespace where the rook cluster is running clusterID: rook-ceph-external # Ceph pool into which the RBD image shall be created pool: replicated_2g # RBD image format. Defaults to "2". imageFormat: "2" # RBD image features. Available for imageFormat: "2". CSI RBD currently supports only `layering` feature. imageFeatures: layering # The secrets contain Ceph admin credentials. csi.storage.k8s.io/provisioner-secret-name: rook-csi-rbd-provisioner csi.storage.k8s.io/provisioner-secret-namespace: rook-ceph-external csi.storage.k8s.io/controller-expand-secret-name: rook-csi-rbd-provisioner csi.storage.k8s.io/controller-expand-secret-namespace: rook-ceph-external csi.storage.k8s.io/node-stage-secret-name: rook-csi-rbd-node csi.storage.k8s.io/node-stage-secret-namespace: rook-ceph-external # Specify the filesystem type of the volume. If not specified, csi-provisioner # will set default as `ext4`. Note that `xfs` is not recommended due to potential deadlock # in hyperconverged settings where the volume is mounted on the same node as the osds. csi.storage.k8s.io/fstype: ext4 # Delete the rbd volume when a PVC is deleted reclaimPolicy: Delete allowVolumeExpansion: true EOF
You can now create a persistent volume based on this StorageClass.
CephCluster example (management)
The following CephCluster CR represents a cluster that will perform management tasks on the external cluster. It will not only act as a consumer but will also allow the deployment of other CRDs such as CephFilesystem or CephObjectStore. As mentioned above, you would need to inject the admin keyring for that.
The corresponding YAML example:
apiVersion: ceph.rook.io/v1
kind: CephCluster
metadata:
name: rook-ceph-external
namespace: rook-ceph-external
spec:
external:
enable: true
dataDirHostPath: /var/lib/rook
cephVersion:
image: quay.io/ceph/ceph:v16.2.7 # Should match external cluster version
Deleting a CephCluster
During deletion of a CephCluster resource, Rook protects against accidental or premature destruction of user data by blocking deletion if there are any other Rook-Ceph Custom Resources that reference the CephCluster being deleted. Rook will warn about which other resources are blocking deletion in three ways until all blocking resources are deleted:
- An event will be registered on the CephCluster resource
- A status condition will be added to the CephCluster resource
- An error will be added to the Rook-Ceph Operator log
Cleanup policy
Rook has the ability to cleanup resources and data that were deployed when a CephCluster is removed.
The policy settings indicate which data should be forcibly deleted and in what way the data should be wiped.
The cleanupPolicy
has several fields:
confirmation
: Only an empty string andyes-really-destroy-data
are valid values for this field. If this setting is empty, the cleanupPolicy settings will be ignored and Rook will not cleanup any resources during cluster removal. To reinstall the cluster, the admin would then be required to follow the cleanup guide to delete the data on hosts. If this setting isyes-really-destroy-data
, the operator will automatically delete the data on hosts. Because this cleanup policy is destructive, after the confirmation is set toyes-really-destroy-data
Rook will stop configuring the cluster as if the cluster is about to be destroyed.sanitizeDisks
: sanitizeDisks represents advanced settings that can be used to delete data on drives.method
: indicates if the entire disk should be sanitized or simply ceph’s metadata. Possible choices are ‘quick’ (default) or ‘complete’dataSource
: indicate where to get random bytes from to write on the disk. Possible choices are ‘zero’ (default) or ‘random’. Using random sources will consume entropy from the system and will take much more time then the zero sourceiteration
: overwrite N times instead of the default (1). Takes an integer value
allowUninstallWithVolumes
: If set to true, then the cephCluster deletion doesn’t wait for the PVCs to be deleted. Default is false.
To automate activation of the cleanup, you can use the following command. WARNING: DATA WILL BE PERMANENTLY DELETED:
kubectl -n rook-ceph patch cephcluster rook-ceph --type merge -p '{"spec":{"cleanupPolicy":{"confirmation":"yes-really-destroy-data"}}}'
Nothing will happen until the deletion of the CR is requested, so this can still be reverted. However, all new configuration by the operator will be blocked with this cleanup policy enabled.
Rook waits for the deletion of PVs provisioned using the cephCluster before proceeding to delete the cephCluster. To force deletion of the cephCluster without waiting for the PVs to be deleted, you can set the allowUninstallWithVolumes to true under spec.CleanupPolicy.
-
Configure an object store, shared filesystem, or NFS resources in the local cluster to connect to the external Ceph cluster ↩